mirror of
https://github.com/godotengine/buildroot.git
synced 2026-01-04 06:10:16 +03:00
acpid: use shutdown for poweroff, if available, not /sbin/poweroff
It's preferable to use "shutdown -hP now" to ensure that the runlevel is
known, preventing this message on the system console and log:
WARNING: could not determine runlevel - doing soft poweroff
(it's better to use shutdown instead of poweroff from the command line)
Signed-off-by: Carlos Santos <casantos@datacom.com.br>
Signed-off-by: Thomas Petazzoni <thomas.petazzoni@bootlin.com>
This commit is contained in:
committed by
Thomas Petazzoni
parent
1d3e682b12
commit
ab842ce21d
@@ -15,9 +15,15 @@ define ACPID_INSTALL_INIT_SYSV
|
||||
$(TARGET_DIR)/etc/init.d/S02acpid
|
||||
endef
|
||||
|
||||
ifeq ($(BR2_INIT_SYSV)$(BR2_INIT_SYSTEMD),y)
|
||||
ACPID_POWEROFF_CMD = /sbin/shutdown -hP now
|
||||
else
|
||||
ACPID_POWEROFF_CMD = /sbin/poweroff
|
||||
endif
|
||||
|
||||
define ACPID_SET_EVENTS
|
||||
mkdir -p $(TARGET_DIR)/etc/acpi/events
|
||||
printf "event=button[ /]power\naction=/sbin/poweroff\n" \
|
||||
printf 'event=button[ /]power\naction=%s\n' '$(ACPID_POWEROFF_CMD)' \
|
||||
>$(TARGET_DIR)/etc/acpi/events/powerbtn
|
||||
endef
|
||||
|
||||
|
||||